This Article Applies From:
CVI Fusion 6.15 | Infinity Client 6.15 | Infinity Module -- | Core Services -- | DeMeter -- | CVI Net Web -- |
Introduction
The following article explains how to configure a Desoutter Delta Wrench WLAN so that it can be controlled by an Infinity Client station. It also covers the correct asset to use in your Pivotware process and any advanced settings available.
Contents1.2 Open Protocol Configuration |
Wrench Configuration
The Desoutter Delta Wrench WLAN is capable of being controlled by an integrating party however it is necessary to make some small changes to the configuration in order to define the correct way of working.
It is possible to configure one of two different communications when communicating with a Delta Wrench WLAN.
- All Delta Wrench WLAN's firmware versions have the capacity to function using a Desoutter Protocol (WLAN)
- If your Delta Wrench has firmware version 2.3a or newer loaded, then it is possible to use Open Protocol (OP) communication instead of the standard Desoutter one.
See below for which changes are required in a Delta Wrench WLAN for both communication types in order to allow remote control by Infinity Client.
The following Delta Wrench WLAN tool settings have been set using Delta QC. To get the download link please see here |
WLAN Configuration
Inside of the Configuration Menu:
- The wrench's source type must be set to "WLAN"
Inside of the WLAN Settings menu:
- The Status must be Enabled
- The SSID, IP Address Settings and Communication Port must be defined
- The Security details for the defined SSID must be defined
Open Protocol Configuration
Inside of the Configuration Menu:
- The wrench's source type must be set to "WLAN"
Inside of the Open Protocol Settings menu:
- The Status must be Enabled
- The SSID, IP Address Settings and Communication Port must be defined
- The Security details for the defined SSID must be defined
Fusion Configuration
Asset Configuration
The type of communication defined in your wrenches configuration will determine the type of asset that you need to configure in Fusion.
- For Wrenches configured to with "WLAN Settings" enabled, it's necessary to configure a Delta Wrench (WLAN) Asset.
- For Wrenches configured to with "Open Protocol Settings" enabled, it's necessary to configure a Delta Wrench (OP) Asset.
WLAN Configuration
Setting Up the Asset In Asset Manager, create a new asset
- Asset Type = Tool - Asset Vendor = Desoutter - Device Type = Delta Wrench (WLAN)
All other options within the asset properties are optional however we suggest filling as much as possible while you're here.
|
Open Protocol Configuration
Setting Up the Asset In Asset Manager, create a new asset
- Asset Type = Tool - Asset Vendor = Desoutter - Device Type = Delta Wrench (OP)
All other options within the asset properties are optional however we suggest filling as much as possible while you're here.
|
Step Configuration
|
Feature Management
From version 7.0 onward, features within the Pivotware software are required to be activated individually. For more information about Feature management, see here
The Infinity Base feature is always required for the Infinity Client application to run. Any other listed features must be additionally activated in order to use the functionality described in this article:
Infinity Base | Wrench Tool |