This Article Applies From:
CVI Fusion 6.6
Infinity Client 6.12
Infinity Module 6.19
Core Services --
DeMeter --
CVI Net Web --


Introduction

The following articles explains how to deploy configurations to Infinity Client and Infinity Modules devices from CVI Fusion


Contents

Deploying Infinity Configurations  
Applying Infinity Configurations - "Deploy to station" 
Applying Infinity Configurations - "Deploy to local folder" 


Deploying Infinity Configurations  


  • Open Configuration Manager
  • Open an existing project

All Infinity Client stations that been created inside of the project are listed in the main workspace with their designated IP Address.

  • Select a station or a individual part of a station's configuration.
  • Click "Deploy to station" to attempt to send the configuration to the defined IP Address. The configuration transfer is automatically handled by CVIFusion.

  • Click "Deploy to local folder" to deploy to a locally accessible folder (for example an USB key). A dialog box will let you choose deployment's target folder.


Green tick icons indicate that a deployment was successful


For Local Folder Deployment, all necessary files (configuration - media - user file...) have been written to the target folder.

 

As of 6.19 it is possible to deploy Infinity Modules in the same way as described above. Use the tabs at the bottom-left of the main workspace to swap between deploying module and process project devices.


Applying Infinity Configurations - "Deploy to station" 


When a new configuration is detected by Infinity Client, the top bar of the HMI flashes ready to notify user that a new configuration can be applied.


  • To apply the new configuration, click the Infinity logo in the top-left hand corner of the HMI.

  • Click "Apply New Process".


As of 6.19 it is possible to apply Infinity Module Configurations in the same way as described above.


Applying Infinity Configurations - "Deploy to local folder" 


It is possible to deploy a process using files saved to a local folder.

  • If necessary, copy all files saved to the target local folder to an USB key (skip this step if the target folder already is an USB key).
  • Connect the USB key to the target Infinity station.
  • Copy all files retrieved from the deployment to the following folder: C:\ProgramData\Desoutter\ProcessControl\InfinityClient\Inbound.
  • Infinity detects automatically that a new process is available for deployment: click the Infinity Logo in the upper left corner.
  • Click the Manage Process icon.
  • Click Apply new process to deploy the latest uploaded process.

The process will be deployed, and all data will be cleared from the Inbound folder.